Tuesday, March 20, 2012

Sick Lincoln stick welder

If it's a buzzbox AC only welder, I'd start with the switch, and I'd ohm out the primary winding. Unplugged and power off, of course. I've seen some newer aluminum winding transformer type welders go open at a crimped on lug. Could also happen to copper, but much more of a problem with Al windings.